DIY & repairRay Dutton's Garage5 Humidifier Mistakes That Are Rusting Out Your Furnace (And the Setting That Fixes Dry Air)

5 Humidifier Mistakes That Are Rusting Out Your Furnace (And the Setting That Fixes Dry Air)

Long-form11:11

Published Oct 11, 2026, 6:30 PM · 2d ago

Ray Dutton's Garage
Ray Dutton's Garage
30.4K subscribers · median 7K views
Views
3,698
+1 views/hour
Likes
31
0.8% of views
Comments
1
0.03% of views

Checked every 3 h while the video is this age · last check 45m ago · next in 134 min. YouTube itself updates public counts with a short delay.

Open on YouTube
Views / hour now
1
measured 45m ago
Peak views / hour
10
6h ago
Avg views / day
1.3K
since upload
First 24 hours
—
not tracked from upload
vs channel median
0.5×
Rank in channel
#16
of 20 tracked
Engagement
0.9%
likes + comments / views
Est. ad revenue
$18–$44
lifetime, $5–12 RPM

Views over time

3 readings · line: total views · bars: views gained per hour

Description

🔧 Everything I learned fixing HVAC for 25 years, in one plain-English book. 📘 THE HVAC SURVIVAL GUIDE - get it here: https://raydutton.com That snap of static off the doorknob is dry winter air, and it's why so many furnaces have a humidifier on the ductwork beside them. It runs water over a pad while warm air blows through it. When that water goes anywhere but your air or the drain, it runs into the furnace, and a twenty-dollar pad turns into a control board that can cost seven hundred dollars. I spent twenty-five years walking up to wet furnaces in the winter. In this video I go through the five humidifier mistakes I saw rust them out: the dial everybody reads like a thermostat, the humidifier wired to the fan instead of the heat, the pad nobody changed, the drain hose, and the slow leak inside you can't see from outside. For each one I show you how to check it yourself, what the fix costs, and the right setting for dry air. At 20 degrees outside, that's about 35 percent humidity inside. CHAPTERS 0:00 Static shocks and the humidifier on your furnace 0:36 1. Reading the dial like a thermostat 1:12 Why a dial turned all the way up never shuts off 1:47 The setting that fixes dry air 2:39 2. Wired to the fan instead of the heat 3:49 The 5-minute drain hose test 4:24 The one humidifier this doesn't apply to 5:03 3. The pad nobody changed 5:43 Changing the pad 6:04 No water at all: the valve and the summer setting 7:09 4. The drain hose 7:57 The 2-minute hose check 8:24 5. The slow leak inside 8:51 Where the water lands, and what it costs 9:49 How to catch it early 10:10 The question to ask before a new board What number is your humidifier dial on right now? Tell me in the comments. I read every one. I'm Ray Dutton. Keep your cool, and I'll see you in the next one. #humidifier #furnace #dryair #hvac #wholehousehumidifier #furnacerepair #hvactips #homemaintenance
Tags
furnace humidifierwhole house humidifierhumidifier setting winterhumidifier pad replacementaprilaire humidifierhumidifier leakinghumidifier drain linehumidistat settingdry air in winterfurnace rustfurnace control boardhumidifier solenoid valvebypass damperRay Duttonhvac tips

Statistics from the YouTube Data API, tracked by FameX. Views per hour, revenue and comparisons are FameX estimates.